Installation, Gt remote installation – Regency Liberty L390PB Medium Gas Insert User Manual

Page 19

Advertising
background image

L

390

PB-2 / HZI

390

PB-2 Direct Vent Gas Insert

19

INSTALLATION

GT REMOTE INSTALLATION

Note: GT remote control installation must be completed prior to the unit

being installed.

1. Bring the TH and TP-TH wires around back of the unit to the right side -

where the valve is located.

GT Remote Receiver Components

1

946-680

GT remote control

2. Connect the TH/TP-TH wires from the harness to the valve terminals also

marked TH/TP-TH - locations as shown below.

3. Secure cable ties to the unit as shown by inserting cable ties into round

holes. There will be a total of 4 cable ties that need to be inserted into the
holes. (2 on the back and 2 on the left side located on the lower side of
the fi rebox).

TPTH Wire

TH Wire

4. Install receiver onto backing plate with 2 screws and plug in receiver w
.

Cable Tie

Wire Clip

Left

Right

Cable Tie

Cable Tie

4. Bundle excess wires - with the exception of the wire marked receiver.
Receiver wire requires enough slack to reach the front left of the unit t

be connected to the receiver.

Secure wires with cable ties installed in previous step.
Additionally secure wires with a wire clip to be installed in location show

below.

5. Connect receiver wire from the wiring harness to the back side of the

remote receiver as shown below

8. Bundle excess receiver wire using a cable tie and secure to the front le

of the fi rebox as shown below.