PB-2 Direct Vent Gas Insert

INSTALLATION

GAS PIPE PRESSURE

TESTING

The appliance must be isolated from the gas sup-
ply piping system by closing its individual manual
shut-off valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psig. (3.45 kPa). Disconnect
piping from valve at pressures over 1/2 psig.

The manifold pressure is controlled by a regulator
built into the gas control, and should be checked
at the pressure test point.

Note: To properly check gas pressure, both

inlet and manifold pressures should
be checked using the valve pressure
ports on the valve.

1) Make sure the valve is in the "OFF" position.

2) Loosen the "IN" and/or "OUT" pressure tap(s),

turning counterclockwise with a

1/8" wide fl at screwdriver.

3) Attach manometer to "IN" and/or "OUT"

pressure tap(s) using a 5/16" ID hose.

4) Light the pilot and turn the valve to "ON"

position.

5) The pressure check should be carried out with

HIGH ELEVATION

This unit is approved for altitude 0 to 4500 ft. (CAN1
2.17-M91).

GAS LINE

INSTALLATION

Since some municipalities have additional local
codes it is always best to consult with your local
authorities and the CAN/CGA B149 installation
code.

For USA installations follow local codes and/or the
current National Fuel Gas Code, ANSI Z223.1.

When using copper or fl ex connectors use only
approved fi ttings. Always provide a union so that
gas lines can be easily disconnected for servicing.
Flare nuts for copper lines and fl ex connectors are
usually considered to meet this requirement.

NOTE: A shutoff / dante valve should be sup-
plied in or near the unit (or as per local codes)
for ease of servicing this appliance.

IMPORTANT: Always check for gas leaks with
a soap and water solution or gas leak detector.
Do not use open fl ame for leak testing.

L390PB NG2 / HZI390PB NG2

SYSTEM DATA

Min. Supply Pressure

5" WC (1.25 kpa)

Manifold Pressure

3.5" WC (0.87 kpa)

Orifi ce Size

#35 DMS

Maximum Input

31,000 Btu/h
(9.09 kW)

L390PB LP2 / HZI390PB LP2

SYSTEM DATA

Min. Supply Pressure

11" WC (2.73 kpa)

Manifold Pressure

10" WC (2.49 kpa)

Orifi ce Size

#53 DMS

Maximum Input

31,000 Btu/h
(9.09 kW)

820 S.I.T. VALVE

DESCRIPTION

Top View of pilot fl ame

Top View of pilot fl ame

Incorrect fl ame pattern will have small, probably
yellow fl ames, not coming into proper contact
with the rear of the burner or thermopile.

If you have an incorrect fl ame pattern, contact
your Regency dealer for further instructions.

the unit burning and the setting should be within
the limits specifi ed on the safety label.

6) When fi nished reading manometer, turn off the

gas valve, disconnect the hose and tighten the
screw (clockwise) with a 1/8" fl at screwdriver.
Note: Screw should be snug, but do not over
tighten.

1

2

3

4

5

IN

OUT

7

8

6

1) Gas on/off knob
2) High/low

adjustment

3) Pilot

Adjustment

4) Manifold (Outlet) Pressure Tap
5) Inlet

Pressure

Tap

6) Pilot Outlet
7) Main Gas Outlet
8) Alternative TC Connection Point