20

L

390

PB-2 / HZI

390

PB-2 Direct Vent Gas Insert

INSTALLATION

GTM REMOTE INSTALLATION

Note: GTM remote control installation must be completed prior to the unit

being installed.

1. Bring the TH, TPTH, and Stepper motor wires around back of the unit to

the right side - where the valve is located.

GTM Remote Receiver Components

1

946-681

GTM remote control

1 946-683

(or)
946-984

Stepper Motor (NG) (sold separately)

Stepper Motor (LP) (sold separately)

2. Connect the TH/TP-TH wires from the harness to the valve terminals also

marked TH/TP-TH - locations as shown below.

3. Install stepper motor (installation instructions provided by SIT).

4. Connect the stepper motor wire (marked stepper) from the harness into

the stepper motor wire on the motor.

5. Secure cable ties to the unit as shown by inserting cable ties into round

holes. There will be a total of 4 cable ties that need to be inserted into th
holes. (2 on the back and 2 on the left side located on the lower side of
the fi rebox).

TPTH Wire

TH Wire

6. Bundle excess wires - with the exception of the wire marked receiver.
Receiver wire requires enough slack to reach the front left of the unit to

be connected to the receiver.

Secure wires with cable ties installed in previous step.
Additionally secure wires with a wire clip to be installed in location

shown below.

Cable Tie

Wire Clip

Left

Right

Cable Tie

Cable Tie

Receiver Wire