1 wire sizes – Baldor MN1940 User Manual

Page 19

Advertising
background image

www.baldormotion.com

Input / Output 4-3

MN1940

4.2.1 Wire sizes

Table 1 describes the wire sizes to provide optimal protection against EMI and RFI. Correct
wire size is determined by the current requirement and the cable length. The actual cable type,
wire gauge, shield type and filtering devices used are dependent on the customer’s application
and system. Always use shielded twisted pairs for AC and DC supply cables. For logic wiring
(see section 4.3) AWG22 wire is recommended.

Supply current

Cable length

(meters)

Cable length

(feet)

Minimum

Wire Gauge

(

)

(

)

AWG

mm

2

3

10

20

0.5

8

25

20

0.5

1 A peak

15

50

18

1.0

p

23

75

18

1.0

30

100

16

1.3

3

10

20

0.5

8

25

18

1.0

2 A peak

15

50

16

1.3

p

23

75

14

2.0

30

100

14

2.0

3

10

18

1.0

8

25

16

1.3

3 A peak

15

50

14

2.0

p

23

75

12

3.3

30

100

12

3.3

3

10

18

1.0

8

25

16

1.3

4 A peak

15

50

14

2.0

p

23

75

12

3.3

30

100

12

3.3

Table 1 - Power wire ratings

Advertising