Connection summary, 5 connection summary - minimum system wiring – Baldor MN1940 User Manual

Page 26

Advertising
background image

www.baldormotion.com

4-10 Input / Output

MN1940

4.5 Connection summary - minimum system wiring

As a guide, Figure 13 shows an example of the typical minimum wiring required to operate the
DSM in conjunction with a NextMove ESB controller.

X2

X12

Motor

power

supply

NextMove ESB

Red - 12-48 VDC / 12-75 VDC
Black - 0 V

Orange - Step clock

White - Optocoupler reference

Blue - Direction

Brown - Enable

DSM

Ferrite & filter
not shown.

PC USB port > SPI connection

(required only during setup)

PC

CBL055-501

DIR0+

+5V

STEP0

(NC)

DGND

REL COM

REL NC

Note: For simplicity, the NextMove ESB’s 24 V
power supply on connector X1 is not shown.

Figure 13 - Example minimum system wiring (flying leads)

Advertising