Rockwell Automation 25B PowerFlex 520-Series Adjustable Frequency AC Drive Quick Start User Manual

Page 14

Advertising
background image

14

Rockwell Automation Publication 520-QS001A-EN-E - March 2014

PowerFlex 520-Series Adjustable Frequency AC Drive

PowerFlex 525 Control I/O Terminal Designations

No.

Signal

Default

Description

Parameter

R1

Relay 1 N.O.

Fault

Normally open contact for output relay.

t076

R2

Relay 1 Common

Fault

Common for output relay.

R5

Relay 2 Common

Motor Running

Common for output relay.

t081

R6

Relay 2 N.C.

Motor Running

Normally closed contact for output relay.

01

Stop

Coast

Three wire stop. However, it functions as a stop under all input modes and cannot be disabled.

P045

02

DigIn TermBlk 02/
Start/Run FWD

Run FWD

Used to initiate motion and also can be used as a programmable digital input. It can be programmed with t062 [DigIn
TermBlk 02] as three wire (Start/Dir with Stop) or two wire (Run FWD/Run REV) control. Current consumption is 6 mA.

P045, P046,
P048, P050,
A544, t062

03

DigIn TermBlk 03/
Dir/Run REV

Run REV

Used to initiate motion and also can be used as a programmable digital input. It can be programmed with t062 [DigIn
TermBlk 02] as three wire (Start/Dir with Stop) or two wire (Run FWD/Run REV) control. Current consumption is 6 mA.

t063

04

Digital Common

Return for digital I/O. Electrically isolated (along with the digital I/O) from the rest of the drive.

05

DigIn TermBlk 05

–Preset Freq

Program with t065 [DigIn TermBlk 05]. Current consumption is 6 mA.

t065

06

DigIn TermBlk 06

–Preset Freq

Program with t066 [DigIn TermBlk 06]. Current consumption is 6 mA.

t066

07

DigIn TermBlk 07/
Pulse In

Start Source 2
+ Speed
Reference2

Program with t067 [DigIn TermBlk 07]. Also functions as a Pulse Train input for reference or speed feedback. The
maximum frequency is 100 kHz. Current consumption is 6 mA.

t067

08

DigIn TermBlk 08

Jog Forward

Program with t068 [DigIn TermBlk 08]. Current consumption is 6 mA.

t068

C1

C1

This terminal is tied to the RJ-45 port shield. Tie this terminal to a clean ground in order to improve noise immunity
when using external communication peripherals.

C2

C2

This is the signal common for the communication signals.

S1

Safety 1

Safety input 1. Current consumption is 6 mA.

S2

Safety 2

Safety input 2. Current consumption is 6 mA.

S+

Safety +24V

+24V supply for safety circuit. Internally tied to the +24V DC source (Pin 11).

11

+24V DC

Referenced to Digital Common. Drive supplied power for digital inputs. Maximum output current is 100 mA.

12

+10V DC

Referenced to Analog Common. Drive supplied power for 0...10V external potentiometer.
Maximum output current is 15 mA.

P047, P049

13

±10V In

Not Active

For external 0-10V (unipolar) or ±10V (bipolar) input supply or potentiometer wiper.
Input impedance: Voltage source = 100 kW

Allowable potentiometer resistance range = 1...10 kW

P047, P049,
t062, t063,
t065, t066,
t093, A459,
A471

14

Analog Common

Return for the analog I/O. Electrically isolated (along with the analog I/O) from the rest of the drive.

15

4-20mA In

Not Active

For external 4-20 mA input supply.
Input impedance = 250 W

P047, P049,
t062, t063,
t065, t066,
A459, A471

16

Analog Output

OutFreq 0-10

The default analog output is 0-10V. To convert a current value, change the Analog Output jumper to 0-20 mA. Program
with t088 [Analog Out Sel]. Maximum analog value can be scaled with t089 [Analog Out High].
Maximum Load: 4-20 mA = 525 W (10.5V)

0-10V = 1 kW (10 mA)

t088, t089

17

Opto Output 1

Motor Running

Program with t069 [Opto Out1 Sel].
Each Opto-Output is rated 30V DC 50 mA (Non-inductive).

t069, t070,
t075

18

Opto Output 2

At Frequency

Program with t072 [Opto Out1 Sel].
Each Opto-Output is rated 30V DC 50 mA (Non-inductive).

t072, t073,
t075

19

Opto Common

The emitters of the Optocoupler Outputs (1 and 2) are tied together at Optocoupler Common. Electrically isolated from
the rest of the drive.

Advertising
This manual is related to the following products: