8. Cleaning Air Duct

8. CLEANING AIR DUCT

Overview

Cleaning the Blower on top of the Projector Head

Cleaning the Dust filters

8.1 Cleaning the Blower on top of the Projector Head

This item should be cleaned approximately every six months under normal environment conditions. Equip-
ment in very dusty or otherwise contaminated areas may require more frequent maintenance.

C

AUTION

:

Power off the projector, using the main power switch on the projector pedestal and allow cooling

of the Xenon bulb lamp for at least 15 minutes before proceeding to blower cleaning.

How to clean the Blower

The blower impeller and motor should be cleaned to prevent build up of contaminant on both the blower impeller surfaces and on
the blower motor. Proper operation of the lamp is dependent on providing adequate cooling air flow. A dirty blower may not provide
proper air flow, causing the lamp and lamp house to operate at temperatures that are higher than desirable.

1. Remove the lamp house to access the blower (see "Removal of the Lamp Unit", page 23)

2. Clean loose dirt from blower impeller with vacuum cleaner. (image 8-1)

3. Use brush with hot water and suitable detergent to remove dirt that cannot be vacuumed off.

Lamp house removed

Image 8-1
Exhaust blower

8.2 Cleaning the Dust filters

These items should be cleaned monthly under normal environment conditions. Equipment in very dusty or
otherwise contaminated areas may require more frequent maintenance.

If the air filters are not regularly cleaned, the air flow inside the projector could be disrupted and cause over-
heating. Overheating may lead to the projector shutting down during operation.

R5976907 D-CINE PREMIERE DP100 02/11/2005