Rockwell Automation 1336T Master/Slave Parallel AC Drv User Manual
Page 21
1336 FORCE-5.19 – August, 2000
Startup
3-3
Data Checks- Record motor and drive data and settings in the
following checklists.
Figure 3.1
Nameplate Data
Motor Lead Checks- Disconnect all motor leads from Drive and
Motor. Megger to ground and to each other.
A. Measure U - Gnd, V - Gnd and W - Gnd (This will be very high
resistance), for both master and slave and record this data.
Data
Parameter
Setting
Motor Nameplate Horsepower
#228
Hp
Motor Base Speed
#229
rpm:
Motor Rated Current
#230
amps:
Motor Rated Voltage
#231
Volts:
Motor Nameplate Frequency
#232
Hz:
Number of Motor Poles
(Poles = (120xrated freq.) / Sync. Speed)
#233
#:
Encoder PPR
#235
PPR:
Rated Inverter Output Amps
#220
Rated Inverter Input Voltage
#221
Main Control Board
Rev Level:
PLC Comm Board (Optional)
Rev Level:
Switch Settings:
J5:
J10:
J13:
Standard Adapter Board (Optional)
Rev Level:
Jumper Settings:
U2:
U3:
U4:
U5:
Encoder Name Plate Data
Catalog No.:
Serial No.:
Series:
Motor Name Plate Data
Serial No.:
Series:
Catalog No.:
Drive Name Plate Data
Serial No.:
Catalog No.:
Series: