Rockwell Automation 1336T Master/Slave Parallel AC Drv User Manual

Page 38

Advertising
background image

1336 FORCE-5.19 – August, 2000

3-20

Startup

Special Commands

The following commands can be used for running the drive
through DriveTools or a handheld GPT/HIM (see 1336 FORCE
User Manual for additional information):

P367{ChA Logic Cmd In}or P368 {ChB Logic Cmd In}= 8208

ACTION: Start from GPT, run at P119 {Preset Speed 1}

P367{ChA Logic Cmd In}or P368{ChB Logic Cmd In} = 8209
ACTION: Stop from DriveTools

P367{ChA Logic Cmd In}or P368{ChB Logic Cmd In}= 8210
ACTION: Start from DriveTools, run at P119 {Preset Speed 1}

P367{ChA Logic Cmd In}or P368{ChB Logic Cmd In} = 4113
ACTION: Stop from DriveTools

P367{ChA Logic Cmd In}or P368{ChB Logic Cmd In} = 4114
ACTION: Start from DriveTools, run at P101 {Velocity
Reference 1 HI}