Calculating the power supply loading – Rockwell Automation 1747-ACNR15 ControlNet Adapter Module User Manual User Manual

Page 127

Advertising
background image

Publication 1747-UM003A-EN-P

Understanding Your SLC 500/1746 Control System B-35

Once you have determined which way you will calculate the heat dissipation of
your modules, Refer to Example - Worksheet for Calculating Heat Dissipation
on page B-40.
This worksheet shows you how to calculate the heat dissipation
for the example 1747-ACN15/-ACNR15 system on Page B-39. Once you feel
comfortable with the layout of the worksheet, go to the worksheet on
Page B-41 and fill it out for your control system.

Calculating the Power Supply Loading

Use the tables below to calculate the power supply loading for each chassis that
you have (step 1 of the worksheet).

Table B.5 Input Module Heat Dissipation

Catalog Numbers

Watts per Point

Minimum Watts

Total Watts

1747-IA4

0.27

0.175

1.30

1746-IA8

0.27

0.250

2.40

1746-IA16

0.27

0.425

4.80

1746-IB8

0.20

0.250

1.90

1746-IB16

0.20

0.425

3.60

1746-IC16

0.22

0.425

3.95

1746-IG16

0.02

0.700

1.00

1746-IH16

0.32

0.217

5.17

1746-IM4

0.35

0.175

1.60

1746-IM8

0.35

0.250

3.10

1746-IM16

0.35

0.425

6.00

1746-IN16

0.35

0.425

6.00

1746-ITB16

0.20

0.425

3.60

1746-ITV16

0.20

0.425

3.60

1746-IV8

0.20

0.250

1.90

1746-IV16

0.20

0.425

3.60

Table B.6 Output Module Heat Dissipation

Catalog Numbers

Watts per Point

Minimum Watts

Total Watts

1746-OA8

1.000

0.925

9.00

1746-OA16

0.462

1.850

9.30

1746-OAP12

1.000

1.850

10.85

1746-OB6EI

0.440

0.230

2.90

1746-OB8

0.775

0.675

6.90

Advertising