3 - hardware setup, What this chapter contains, Installing the 1770-kfd module – Rockwell Automation 1747-SDN SLC 500 DeviceNet Scanner Module User Manual User Manual

Page 31: Chapter 3, Hardware setup, Chapter

Advertising
background image

31

Publication 1747-UM655B-EN-P - June 2007

Chapter

3

Hardware Setup

What This Chapter Contains

This chapter describes how to set up the hardware for the example
application. The following table describes what this chapter contains
and where to find specific information.

Installing the 1770-KFD
Module

Connect the RS-232 connector on the 1770-KFD communication
interface module to one of the serial ports on your computer
workstation (COM1). Connect the DeviceNet connector on the
1770-KFD module to a DeviceNet drop or trunk cable. You can make
this connection in several ways; for example, by using a DeviceNet
Quad Tap (catalog number 1492-DN3TW) as shown on page 45.

Topic

Page

Installing the 1770-KFD Module

31

Installing the SLC 500 Processor

32

Installing the ControlNet RS-232 Interface
Module

35

Installing the 1747-SDN Module

40

Installing the RediSTATION Operator
Interface

43

Installing the Series 9000 Photoeye

44

How Your Network Will Look

45

To computer COM

1770-KFD RS-232 Interface
Module

DeviceNet Dropline or
Trunk Cable

To DeviceNet Network

Advertising