Resolve firmware upgrade issues – Rockwell Automation 2711C-xxxx PanelView Component HMI Terminals User Manual

Page 137

Advertising
background image

Publication 2711C-UM001I-EN-P - July 2014

137

Firmware Update Utility Appendix E

9. Check that the terminal reverts to the startup application.

Resolve Firmware Upgrade
Issues

If you experience problems with the firmware update utility, check that your USB
RNDIS adapter settings are correct.

1. Open the Windows Network Connections folder

2. Reset the Terminal.

3. Right-click the connection with name Allen-Bradley PanelView Boot

Loader USB Remote RNDIS Network Device when it appears, then select
Properties. Note that this connection will disappear after a few seconds).

TIP

Momentarily open the USB connection at the same time
power is cycled. Otherwise, the power from the USB
connection may prevent the terminal from resetting.