Configuration Mode Chapter 2

Configure the Screen Saver

You can enable or disable the screen saver on the connected PanelView
Component terminal.

The terminal has four screen saver modes: screen saver, dimmer, screen saver and
dimmer, or disable.

• Screen saver – activates after the idle timeout elapses using a default screen

saver image. The screen saver deactivates when you press a key.

• Dimmer – dims the display from full brightness to the brightness level you

set when the idle timeout elapses. While the display is dimmed, you can
still see on-screen activity. When you press a key, the display is restored to
full brightness.

• Screen saver and dimmer – activates the screen saver and dims the display

when the idle timeout elapses.

• Disable screen saver and dimmer – keeps the display on.

The screen saver timeout is the amount of idle time that must elapse before the
screen saver, dimmer, or screen saver and dimmer activates. The idle time can be
adjusted between 1…60 minutes.

The brightness intensity of the screen saver or dimmer can be adjusted between
1…100%.

Follow these steps to configure the screen saver using the PanelView Explorer
Startup window.

1. Go to the PanelView Explorer Startup window.

2. Click the Terminal Settings link.

3. Click the Display/Input tab.

4. Select a screen saver mode from the list.

5. Select a time from the pull-down list to adjust the screen saver timeout.