15Ć2

AutoMax Programming Executive Version 3.x

15.1

Running an Individual Task

WARNING

THIS COMMAND OVERRIDES THE NORMAL STARTING SEQUENCE OF THE

APPLICATION TASKS, WHICH IS DETERMINED BY THE PRIORITY ASSIGNED

WHEN THEY ARE ADDED TO THE RACK. THE RUN ALL OPTION SHOULD

NORMALLY BE USED TO START TASKS. FAILURE TO OBSERVE THIS

PRECAUTION COULD RESULT IN BODILY INJURY.

Follow the directions below to put an individual task into run:
1. Select the task to be run from those displayed on the ON LINE

menu. To select the task, use the up and down arrow keys to

move the >" pointer to the desired task.

2. Type the Enter" or <CR> key. The selected task will be shown

in reverse video.

3. Type R" to put the task into run. The task Status" field on the

display will show that the task is in RUN.

Note that UDC tasks can be run regardless of whether the PMI is

communicating with the UDC.

15.2

Running All Tasks in the Rack

To run all AutoMax and UDC tasks in the rack, including utility tasks,

using the procedure described in this section, all tasks in the rack

except utility tasks must be loaded in the rack. If this is not the case,

the screen will display an error message and no tasks will be put into

run.
Follow the directions below to put all tasks in the rack into run:
1. Do not select an individual task while at the ON LINE menu.

Instead, type R" from the ON LINE menu with no task selected.

This results in the display shown in figure 15.1.

Advertising