Light Curtain Multi-Function Control Module User Manual

Original instructions

5.3.3.3. Menu “Safety information”

Gives important safety information for installing and operating the software.

5.3.3.4. Menu “About”

Displays the welcome window to check software version.

5.4. Main window

Three main tabs are available to choose from (

Figure 20):

1. Design

(See chapter 5.4.1 on page 18)

2. Diagnosis

(See chapter 5.4.2 on page 21)

3. Application info

(See chapter 5.4.3 on page 22)

5.4.1. Tab “Design”

In the design window two sub-tabs are available (1,

Figure 25):

1. Configuration

(See chapter 5.4.1.1 on page 18)

2. Basic configuration

(See chapter 5.4.1.2 on page 20)

5.4.1.1. Configuration

This tab offers the possibility to specify the type and the properties of the safety components that can be controlled. By clicking on the pull-down
windows in the area “Inputs” (2,

Figure 25) the following options may be selected:

A

Micro 400

• None

An MSR42 control unit can also be used for safety functions without a Micro 400 safety light curtain (for example E-Stop, Door-Switch,
overriding of a safety device, muting of a safety device, time delay.)

• Micro 400 light curtain

B GPIO (General Purpose Input / Output

Which signal is connected to the GPIO1 to GPIO4 pins.
• None
• 1 Device (2NC)
• 1 Device (OSSDs)
• 2 Device (OSSDs)
• Override Micro 400
• Override 1 Device (OSSD)
• Muting Micro 400
• Muting other devices (OSSD)

C Input IN1

Which signal is connected to the input IN1
• Test Input
• Start
• None

D Input IN2

Which signal is connected to the input IN2
• Start
• EDM
• Start Release
• None