Light Curtain Multi-Function Control Module User Manual

Original instructions

Figure 27: Basic configuration

In this window eight different wiring options of the “Basic configuration” can be displayed. These options can be realized just by wiring any standard,
out of the box MSR42 control unit (Cat. # 440R-P226AGS-NNR). No additional configuration is necessary.

5.4.2. Tab “Diagnosis”

In order to carry out a diagnostic of a MSR42 control unit, the following steps must be made:

1. Connect the Optical Interface

(See chapter 3 on page 8), to the PC and the MSR42

1. Start the MSR42 “Configuration and diagnostic Software” Tool

3. Select the “Diagnosis” tab (1,

Figure 28)

The program immediately detects the MSR42 and displays the transmitted data. Three different functions may be selected (2,

Figure 28):

• Protective field viewer
• Service information
• Muting time recorder

Switch between these functions by choosing the corresponding sub-tab.

5.4.2.1. Protective field viewer

This function graphically shows the interrupted area of the GuardShield Micro 400 light curtain protective field (

Figure 28). The numbers displayed in

this window represent the first and the last interrupted beams. No definite statement can be made with regards to the status of the beams between these
two beams, since this information is not transmitted to the MSR42 Configuration and Diagnostic Software.

Figure 28: Example of a protective field interruption