Floating blanking, Teach-in blanking, Appendix – Rockwell Automation MSR42 Curtains Configuration and Diagnostic Software Tool User Manual User Manual

Page 57: Frequently asked questions (faq), Original instructions

Advertising
background image

55

Light Curtain Multi-Function Control Module User Manual

Original instructions

In the case of "Fixed Blanking" (3 –

Figure 74), the first (4) and last (5) interrupted beams must be defined and thereafter confirmed with a cursor click

on the "Quick check" box (7).

Floating Blanking

Figure 75: Floating Blanking window

In the case of "Floating Blanking" (3 –

Figure 75), the area in which the object is allowed to move must first be defined (4 and 5). Subsequently the

number of interrupted beams for "Floating Blanking" can then be defined (6). Finally, the user must specify whether this application operates with
object monitoring or without object monitoring (7). Finish the blanking configuration for this region by clicking on the Quick check button.
Additional information on floating blanking can be found in

chapter 5.7.3 on page 52.

Teach-in Blanking

Teach-In blanking is available in the Basic Configuration mode

(See chapter 5.4.1.2 on page 20), and does not need to be configured. However if desired

this mode can also be configured (3 –

Figure 73).

6. Appendix

6.1. Frequently Asked Questions (FAQ)

Behavior

Possible Cause

Possible Solution

Download is not possible

Optical Interface is not connected

Connect Optical Interface (Cat. no. 445L-AF6150) to a USB port of your

computer (See chapter 3 on page 8)

USB driver not correctly installed

1.Unplug Optical Interface from USB port
2.Deinstall Configuration SW
3.Reinstall Configuration SW
4.Plug in Optical Interface on a USB port

MSR42 is password protected

Contact the machine manufacturer

(See chapter 5.5.3 on page 35)

Invalid Unit Protection Key (Error 403)

MSR42 is password protected

Contact the machine manufacturer

(See chapter 5.5.3 on page 35)

2

3

1

4

5

8

9

6

7