Parameter object (class id 0fh), Instances, Parameter object (class id 0f – Rockwell Automation 1440-VST02-01RA XM-120 Eccentricity Module User Manual

Page 98

Advertising
background image

Publication GMSI10-UM010C-EN-P - May 2010

90 DeviceNet Objects

Parameter Object
(Class ID 0F

H

)

The Parameter Object provides the interface to the Eccentricity configuration
data. There are 18 Parameter Object instances implemented in the Eccentricity
module.

Instances 1-4 and 7-16 are implemented to provide an alternate method of
setting the configuration parameters with ENGUNIT or EPATH data type.
And Parameter Object instances 17 and 18 provide an alternate method for
setting the Produced Connection Size and Produced Connection Path
attributes for the Poll Connection because these attributes can be difficult to
get/set directly through the Connection Object.

Parameter Object instances 5 and 6 are for setting the update rate of the
eccentricity measurements. The eccentricity update rate is used in place of the
tachometer when no tachometer is available.

Instances

There are 18 instances of this object.

Table C.24 Parameter Object Class Attributes

Attr ID

Access
Rule

Name Data

Type

Description

Semantics

2

Get

Max Instance

UINT

Maximum instance
number of an object in
this class.

Total number of parameter
object instances.

8

Get

Parameter Class
Descriptor

WORD

Bits that describe the
parameter.

Bit 0 Supports Parameter
Instances
Bit 1 Supports Full Attrib.
Bit 2 Must do non-volatile store
Bit 3 Params in non-volatile

9

Get

Config.
Assembly
Instance

UINT

Set to 0

Table C.25 Parameter Object Instances

Instance

Read
Only

Name

Data Type

Valid Values

Default Value

1

No

Transducer 1 Sensitivity Units

USINT

0 = mils
1 = µm

0

2

No

Transducer 2 Sensitivity Units

USINT

0 = mils
1 = µm

0

3

No

Eccentricity Measurement 1
Units

USINT

0 = mils
1 = µm

0

4

No

Eccentricity Measurement 2
Units

USINT

0 = mils
1 = µm

0

Advertising