Fault Isolation Procedures
2-6
Power-Up Sequence Test, continued
Step C
Procedure
Condition
Action
1. Key off.
2. Disconnect Operator Display
Unit from harness J1.
3. Key on.
4. Measure voltage between
sensor harness J2
pins 1 and 2.
If voltage is between 10 and
14 volts
If voltage is outside of range
Replace ODU. Go to Step V.
Replace sensor. Go to Step V.
VOLT