Electrical pretest, Fault isolation procedures, Step a procedure condition action – Bendix Commercial Vehicle Systems BLINDSPOTTER TROUBLESHOOTING GUIDE User Manual

Page 6: Step b procedure condition action

Advertising
background image

Fault Isolation Procedures

2-2

Electrical Pretest

Step A

Procedure

Condition

Action

1. Key off.

2. Inspect starter/battery

connections for integrity.

3. Measure voltage across

battery.

If voltage is 11 to 13 volts
on a 12 volt system or 22 to
26 on a 24 volt system

If voltage is outside of
range

Go to Step B.

Repair or replace batteries and
charging system as required.
Repeat this step.

Step B

Procedure

Condition

Action

1. Key off.

2. Disconnect negative (-) battery

cable.

3. Disconnect the sensor J2 harness.

4. Measure resistance

between sensor harness
J2 pin 2 and ground.

If resistance is 0 to .5 ohms

If resistance is outside of
range

Go to Step C.

Repair ground path to system.
Go to Step A.

OHMS

GROUND

V

A

COM

1

2

3

4

5

6

VOLT

V

A

COM

Advertising