Electrical pretest, continued, Fault isolation procedures electrical pr etest, Step c procedure condition action – Bendix Commercial Vehicle Systems BLINDSPOTTER TROUBLESHOOTING GUIDE User Manual
Page 7
Advertising
Fault Isolation Procedures
Electrical Pr
etest
2-3
Electrical Pretest, continued
Step C
Procedure
Condition
Action
1. Key off.
2. Connect negative (-) battery
cable.
3. Key on.
4. Measure voltage
between sensor harness
J2 pin 1 and ground.
If voltage is within .5 volts
of battery voltage
If voltage is outside of
range
Test complete.
Repair power path to system.
Fuse may be blown. Reconnect all
connectors. Go to Step A.