Side sensor not detecting targets – Bendix Commercial Vehicle Systems BLINDSPOTTER TROUBLESHOOTING GUIDE User Manual

Page 18

Advertising
background image

3-6

Symptom Isolation Procedures

Side Sensor Not Detecting Targets

Step A

Procedure

Condition

Action

Step B

Procedure

Condition

Action

Step V

Procedure

Condition

Action

1. Clear area around sensor of

objects.

2. Key on.

3. Allow Operator Display

Unit to go through self-
test and shows no
targets (yellow LED
light should be on).

1. Key on.

2. Place a target 3 to 10

feet directly in front of
the Sensor.

1. Key off.

2. Reconnect all connectors.

3. Drive vehicle to

determine if problem
has been corrected.

If both LED lights turn on
for .5 seconds – followed by
red LED for 5 seconds –
followed by a continuous
yellow light

If only the yellow LED light
turns on for .5 seconds,
followed by a continuous
yellow light

If both LED lights turn on
for .5 seconds, followed by
continuous yellow and red
lights

If the Operator Display Unit
indicates that a target is
detected (red light on)

If the Operator Display Unit
does not indicate a target is
present (yellow light on)

If complaint has been
repaired

If complaint has not
been repaired

Go to Step B.

Replace Operator Display Unit.

Go to the “Power-Up Sequence
Test” on page 2-4.

Go to Step V.

Replace sensor.

Test complete.

Return to Step A to fi nd
error in testing.