Side sensor continuously detecting targets – Bendix Commercial Vehicle Systems BLINDSPOTTER TROUBLESHOOTING GUIDE User Manual

Page 20

Advertising
background image

3-8

Symptom Isolation Procedures

Side Sensor Continuously Detecting Targets

Step A

Procedure

Condition

Action

Step B

Procedure

Condition

Action

1. Clear area around sensor

of objects.

2. Key on.

3. Allow Operator Display

Unit to go through self-test
and shows no targets
(yellow LED light should
be on).

1. Key on.

2. Remove Sensor from mounting

position.

3. Move Sensor out away from the

vehicle and place in an open area.

4. Key on.

5. Allow Operator Display

Unit to go through self-test
and shows no targets
(yellow LED light should
be on).

If both LED lights turn on
for .5 seconds – followed by
a red LED for fi ve (5) seconds –
followed by a continuous
yellow light

If both LED lights turn on
for .5 seconds, followed by
a continuous red light

If only red LED lights

If both LED lights turn on
for .5 seconds – followed by
a red LED for fi ve (5) seconds –
followed by a continuous
yellow light

If both LED lights turn on
for .5 seconds, followed by
a continuous red light

Go to Step V.

Go to Step B.

Replace Operator Display Unit.

Reposition sensor on vehicle
to allow clear detection zone.
Go to Step V.

Replace sensor. Go to Step V.