Power-up sequence test, Fault isolation procedures, Pow er -up sequence t est – Bendix Commercial Vehicle Systems BLINDSPOTTER TROUBLESHOOTING GUIDE User Manual
Page 9
Advertising
Fault Isolation Procedures
2-5
P
ow
er
-Up Sequence T
est
Power-Up Sequence Test
Step A
Procedure
Condition
Action
Step B
Procedure
Condition
Action
1. Before performing this test, the
Electrical Pretest must pass.
2. Clear area around sensor of objects.
3. Key on.
4. Observe the Operator
Display Unit.
1. Key on.
2. Disconnect sensor harness J2.
3. Key on.
4. Measure voltage
between sensor harness
J2 pins 1 and 2.
If both LED lights turn on
for .5 seconds – followed by
the red LED for 5 seconds –
followed by a continuous
yellow light
If lights fail to turn on
If lights turn on and stay on
If voltage is between 10
and 14 volts
If voltage is outside of
range
Test complete.
Go to Step B.
Go to Step D.
Go to Step C.
Repair harness. Go to Step V.
VOLT
V
A
COM
1
2
3
4
5
6