Bryant SINGLE PACKAGED HEAT PUMP UNITS 657A User Manual

Installation, start-up and operating instructions, 657a single packaged heat pump units

Advertising
background image

NOTE:

Read the entire instruction manual before starting the

installation.

This symbol

indicates a change since the last issue.

TABLE OF CONTENTS

SAFETY CONSIDERATIONS .....................................................1

Introduction ....................................................................................2

RECEIVING AND INSTALLATION ..........................................2

Check Equipment......................................................................2

IDENTIFY UNIT ................................................................2
INSPECT SHIPMENT ........................................................2

Provide Unit Support ................................................................3

ROOF CURB & SLAB MOUNT.......................................3

Provide Clearances....................................................................4
Select and Install Ductwork .....................................................5
Rig and Place Unit....................................................................6

INSTALLATION ................................................................8

Connect Condensate Drain .......................................................9
Install Duct Connections ..........................................................9

CONFIGURING UNITS FOR DOWNFLOW (VERTI-
CAL) DISCHARGE-STANDARD UNITS (024–042)....11
CONFIGURING UNITS FOR DOWNFLOW (VERTI-
CAL) DISCHARGE-ECM UNITS (048–060) .................13

Install Electrical Connection ..................................................14

HIGH-VOLTAGE & CONTROL-VOLTAGE CONNEC-
TIONS................................................................................14
SPECIAL PROCEDURES FOR 208-V OPERATION ...15

PRE-START-UP ..........................................................................15

START-UP ...................................................................................17

CHECK FOR REFRIGERANT LEAKS..........................17
START UP AND MAKE ADJUSTMENTS....................18
CHECKING COOLING CONTROL OPERATION .......18
CHECKING HEATING CONTROL OPERATION........18
CHECKING

AND

ADJUSTING

REFRIGERANT

CHARGE ...........................................................................18
INDOOR

AIRFLOW

AND

AIRFLOW

ADJUST-

MENTS ..............................................................................21
For 208/230v-PSC Blower Motor.....................................21
For 208/230v-ECM Blower Motor ...................................21
COOLING SEQUENCE OF OPERATION.....................22
HEATING SEQUENCE OF OPERATION .....................23

MAINTENANCE.........................................................................23

AIR FILTER......................................................................24
UNIT TOP REMOVAL ....................................................24
INDOOR BLOWER AND MOTOR ................................24
OUTDOOR COIL, INDOOR COIL, AND CONDENSATE
DRAIN PAN......................................................................27
OUTDOOR FAN...............................................................28
ELECTRICAL CONTROLS AND WIRING ..................28
REFRIGERANT CIRCUIT...............................................29
INDOOR AIRFLOW ........................................................29
METERING DEVICE — ACUTROL DEVICE .............29
LIQUID LINE STRAINER ..............................................29

Troubleshooting............................................................................31

Start-Up Checklist ........................................................................32

NOTE TO INSTALLER — Before the installation, READ THESE
INSTRUCTIONS CAREFULLY AND COMPLETELY. Also,
make sure the User’s Manual and Replacement Guide are left with
the unit after installation.

SAFETY CONSIDERATIONS

Installation and servicing of air-conditioning equipment can be
hazardous due to system pressure and electrical components. Only
trained and qualified personnel should install, repair, or service
air-conditioning equipment.

Untrained personnel can perform basic maintenance functions of
cleaning coils and filters. All other operations should be performed
by trained service personnel. When working on air-conditioning
equipment, observe precautions in the literature, tags, and labels
attached to the unit, and other safety precautions that may apply.

Follow all safety codes. Wear safety glasses and work gloves. Use
quenching cloth for unbrazing operations. Have fire extinguisher
available for all brazing operations. Consult a qualified installer or
service agency for information or assistance. The qualified in-
staller or agency must use only factory-authorized kits or acces-
sories when modifying this product.

WARNING:

Before performing service or maintenance

operations on system, turn off power to unit. Turn off
accessory heater power switch, if applicable. Electrical
shock can cause personal injury.

Recognize safety information. This is the safety-alert symbol

.

When you see this symbol in instructions or manuals, be alert to
the potential for personal injury.

Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which will result in

Fig. 1—Unit 657A with Optional Base Rails

C95002

Installation, Start-Up
and Operating Instructions

657A
SINGLE PACKAGED
HEAT PUMP UNITS

Cancels:

II 657A.24.4

II 657A.24.5

7–03

—1—