should be at least 4 in. above the highest expected water and runoff
levels. Do not use unit if it has been under water.

IV.

SELECT AND INSTALL DUCTWORK

The design and installation of the duct system must be in
accordance with the standards of the NFPA (National Fire Protec-
tion Association) for installation of nonresidence-type air condi-
tioning and ventilating systems, NFPA90A or residence type,
NFPA90B; and/or local codes and residence-type, NFPA90B;
and/or local codes and ordinances. Select and size ductwork,
supply-air registers and return-air grilles according to ASHRAE
(American Society of Heating, Refrigeration, and Air Condition-

ing Engineers) recommendations. The unit has duct flanges on the
supply- and return-air openings on the side of the unit. See Fig. 2-5
for connection sizes and locations. When designing and installing
ductwork, consider the following:

CAUTION:

When connecting ductwork to units, do not

drill deeper than 1/2–in. in shaded area shown or coil may
be damaged.

1. All units should have field-supplied filters or accessory

Fig. 5— 657A036-060 Unit Dimensions (with base rails)

UNIT

ELECTRICAL CHARACTERISTICS

UNIT WEIGHT

CORNER WT

LB/KG

CENTER OF GRAVITY

IN/MM

lb.

kg

A

B

C

D

X

Y

Z

657A036

208/230-1-60

336

153

51/23

108/49

86/39

91/41

21.0/535

20.5/521

16.4/418

657A042

208/230-1-60

336

153

51/23

108/49

86/39

91/41

21.0/535

20.5/521

16.4/418

657A048

208/230-1-60

379

172

94/43

86/39

118/54

81/37

19.6/498.3

20.6/524

17.3/440

657A060

208/230-1-60,

393

179

97/44

90/41

121/55

85/39

19.5/497.3

20.6/524

17.3/440

C95006

—5—