DIMENSIONAL DRAWING — 580D090-150

UNIT
580D

STANDARD

UNIT

WEIGHT

CORNER

WEIGHT

(A)

CORNER

WEIGHT

(B)

CORNER

WEIGHT

(C)

CORNER

WEIGHT

(D)

‘‘H’’

‘‘J’’

‘‘K’’

‘‘L’’

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

Ft-in.

mm

090

870

395

189

86

161

73

239

109

280

127

1-2

7

8

378

3-5

5

16

1050

2-9

11

16

856

2- 2

7

16

672

102

880

399

191

87

163

74

242

110

284

129

3-3

7

8

1013

3-5

5

16

1050

2-9

11

16

856

2- 2

7

16

672

120

1035

469

225

102

192

87

285

129

333

151

2-5

7

8

759

4-1

5

16

1253

3-0

3

8

924

2-10

7

16

875

150

1050

476

228

103

195

88

289

131

338

153

1-2

7

8

378

4-1

5

16

1253

3-0

3

8

924

2-10

7

16

875

CONNECTION SIZES

A

1

3

8

Љ

Dia [35] Field Power Supply Hole

B

2-

1

2

Љ

Dia [64] Power Supply Knock-Out

C

1

3

4

Љ

Dia [44] Charging Port Hole

D

7

8

Љ

Dia [22] Field Control Wiring Hole

E

3

4

Љ

—14 NPT Condensate Drain

F

1

2

Љ

—14 NPT Gas Connection 090 125 and 102 125

3

4

Љ

—14 NPT Gas Connection all others

G

2

Љ

Dia [51] Power Supply Knock-Out

NOTES:
1. Dimensions in [

] are in millimeters.

2.

Center of gravity.

3.

Direction of airflow.

4. On vertical discharge units, ductwork to be attached to accessory roof curb only. For

horizontal discharge units field-supplied flanges should be attached to horizontal dis-
charge openings, and all ductwork should be attached to the flanges.

5. Minimum clearance (local codes or jurisdiction may prevail):

a. Between unit (flue side) and combustible surfaces, 48 inches. When using accessory

flue discharge deflector, this is reduced to 18 inches.

b. Bottom of unit to combustible surfaces (when not using curb) 1 inch.

Bottom of base rail to combustible surfaces (when not using curb) 0 inches.

c. Condenser coil, for proper airflow, 36 in. one side, 12 in. the other. The side getting

the greater clearance is optional.

d. Overhead, 60 in. to assure proper condenser fan operation.
e. Between units, control box side, 42 in. per NEC (National Electrical Code).
f. Between unit and ungrounded surfaces, control box side, 36 in. per NEC.
g. Between unit and block or concrete walls and other grounded surfaces, control box

side, 42 in. per NEC.

h. Horizontal supply and return end, 0 inches.

6. With the exception of the clearance for the condenser coil and combustion side as stated

in Notes 5a, b, and c, a removable fence or barricade requires no clearance.

7. Units may be installed on combustible floors made from wood or Class A, B, or C roof

covering material if set on base rail.

8. The vertical center of gravity is 1

Ј

-7

Љ

[483] up from the bottom of the base rail. Horizontal

center of gravity is shown.

BOTTOM POWER CHART, THESE HOLES

REQUIRED FOR USE WITH ACCESSORY

PACKAGES — CRBTMPWR001A00 (

1

2

Љ

,

3

4

Љ

)

OR CRBTMPWR002A00 (

1

2

Љ

, 1

1

4

Љ

)

THREADED

CONDUIT SIZE

WIRE SIZE

REQUIRED HOLE

SIZES (MAX)

1

2

؆

24 V

7

8

Љ

[22.2]

3

4

؆

Power*

1

1

8

Љ

[28.4]

1

1

4

؆

Power*

1

3

4

Љ

[44.4]

*Select either

3

4

Љ

or 1

1

4

Љ

for power, depending on wire size.

8