Trebor Q-Series Di Water Heater User Manual

Page 16

Advertising
background image

PAGE 16

Q-SERIES DI HEATER OPERATION / MAINTENANCE MANUAL

5.2.a Home Page

The Home page is the first page that is displayed after the system power
is enabled. This page is designed to show the current status of the
heater at a glance. The temperature set point (°C), process temperature
(°C), and power usage being applied to the heater outlet (%) are
displayed and buttons allow access to change the temperature set point
and to enable or disable the heating of water.

Buttons F1 and F2 will either increase (

▲) or decrease (▼) the

Temperature Set Point value in 1°C increments.

Button F3 enables (

) or disables (

) the heating of water.

The following navigation buttons are also available for advancing to the
Configuration and Alarm pages:

Button F4 (

) switches the display to the Configuration page

Button F5 (

) switches the display to the Alarm page

F1

F2

F3

F4

F5

Figure 5-1: Home Page

5.2.b Alarm page

The alarm page displays the status of all process interlock alarms (see
section 6 for details of process interlocks). The following list explains the
items on the Alarm Screen:

Pressure = Status of the low fluid pressure interlock