BaseStation 6000 Site Controller Manual

12 |

P a g e

5. In the Communication Setup dialog box, select the Communication Type for the RBU.

If Serial Port is the Communication

Type for the selected Remote Base

Unit, select that option.

If a Mesh Radio is the Communication

Type for the selected Remote Base

Unit, select that option, and then type

the MAC address that is listed on the

Mesh Radio Module of the Remote

Base Unit.

If Network is the Communication

Type for the selected Remote Base

Unit, select that option, and then

type the serial port number and the

IP address for your network.

Note: If your Communication Type is

Radio to Radio to Bridge Unit, select

the Mesh Radio option, and then select

the Bridge Unit check box.

6. Click Return to save your changes and go back to the Base Unit tab.
7. Find the serial number of each RBU. The number is printed on a sticker that is located on the inside door panel of the RBU.

The serial number format is RBXXXXXXX (where the Xs represent a series of seven numbers).

8. In the Serial Number

(4)

field, type the serial number for the first RBU, and then press Enter on the keyboard. The RBU

information displays in the fields.

9. We recommend that you type a description in the Description

(5)

field so you can easily identify the RBU.

10. Repeat these steps for each RBU as needed.

Settings that Apply to Individual RBUs

Disable an RBU – By default, the Device State option is

set to Enabled. If you want to turn off all devices that are

attached to a Remote Base Unit, set the Device State

(1)

for that RBU to Disabled.

Configure the number of zones that can be running at

one time – Under Active Zones

(2)

, type a number in the

Base field to represent the total number of zones that can

be running at one time for this Remote Base Unit. Type a

number in the Device field to represent the total number

of zones that can be running at one time for each biCoder

that is connected to this Remote Base Unit.

Select a different biLine protocol – The BiLine II

(3)

check

box is selected by default, and it means that the Remote

Base Unit will use the biLine II protocol. If you want to

change the protocol to biLine I, click the box to remove

the check mark.