Set an RBU to always apply power – If you have a sensor or other device that requires continuous monitoring attached to

this RBU, select the Always On

(4)

check box to set the Remote Base Unit so it is always applying power to the two-wire

system.

Settings that Apply to All of Your RBUs

Set the total number of zones that can run on the entire system at one time – Type a number in the Total Active Zones

(5)

field to represent the number of zones that can be running on the entire BaseStation 6000 system at one time.
During the initial configuration of your BaseStation 6000, we recommend that you set the Total Active Zones to 1, which

limits the number of zones that can run at one time to only one.

Set the number of zones that can turn on at one time (concurrent zones) – Use the Flow Ramp Up Control

(6)

option to

prevent pump overload by setting the number of zones that will turn on each minute as an watering cycle starts. By default

Flow Ramp Up Control is not enabled. To enable this option, select the check box, and then, in the next field, type the

number of zones that can turn on.

Configuring a Bridge Unit

If your configuration includes a Bridge Unit and backbone wiring, you need to connect your BaseStation 6000 computer to the

Bridge Unit. For the physical installation of the Bridge Unit, please refer to the

“Installation Guide” that was included in the package.

The Communication Setup dialog box opens when you are installing and configuring

the RBUs. When a Bridge Unit is part of your system configuration, select the check

box on the Communication Setup dialog box for each RBU that is connected to that

Bridge Unit.

Adding Valve biCoders and Other Two-Wire Devices

This section describes how to complete the software configuration for the various two-wire devices that are available for the

BaseStation 6000 Site Controller such as biCoders, biSensors, and water flowrate sensors. For the physical installation of the

device in the field, please refer to the “Installation Guide” that was packaged with the device.

Note: We suggest that you attach and configure only a few devices at a time. The system checks your devices. If it detects a

problem, do not add more devices until you correct that problem. Proceed with connecting, configuring, and checking until all

devices are working properly.

Listing Attached Devices

After you have some devices physically connected in the field, you can use the List Devices option in the software to display the

serial numbers of those devices.

1. On the Main Page of the BaseStation 6000 software, click the Remote Base Unit that you

want to list devices for.

2. Click the Information tab to activate the Main Menu.
3. Click the Diagnostics menu, and then click System Diagnostics

(1)

. The System

Diagnostics window opens.

4. Click the Config Support

(2)

tab.