Adding a master valve – Baseline Systems BaseStation 6000 User Manual

Page 25

Advertising
background image

P a g e

| 17

Adding a Master Valve

Any single valve biCoder can be used to operate a master valve. A master valve biCoder can be used to actuate a master valve.

1. On the Main Page of the BaseStation 6000 software, click

the Remote Base Unit that the master valve biCoder is

connected to.

2. Click the Config Zone

(1)

tab.

3. In the Serial Number column, type the serial number for

the master valve biCoder in an unused address line

(2)

.

Note: The serial number of the two-wire biCoder is

located on the side of the unit. The serial number for the

powered biCoder is located on the inside of the

enclosure door.

4. Press Enter on your keyboard. The system searches for

the device, tests the master valve and the

communication, and then displays the Configuration

Status message box.

5. Click OK.
6. Type a description of the master valve biCoder in the Description

(3)

field. Use the description to define the location or area

that this master valve is controlling.

7. Click the arrow in the Device Mode

(4)

field, and then click one of the following options to define the mode of the master

valve:
M-Valve – Used for a normally closed master valve that turns on when the flow zone is activated
M-Val NO – Used for a normally open master valve

8. In the Flow Zone Number

(5)

field, type the number of the flow zone that this master valve controls. Refer to Setting Up

Flow Monitoring for Flow Zones on page 61.

Advertising