BaseStation 6000 Site Controller Manual

16 |

P a g e

Timed – Enables you to set a zone to run based on its programmed times only.

Linked – Sets a zone to use the same watering setting as a previously configured zone.
Note: You are only able to link to a zone with a lower number.

Mirror – Sets a zone to mimic the actions of another zone.
Caution: This mode has a specialized function and is not recommended for general use.

Disabled – Use this mode to disable the zone.
Note: If other zones are mirrored or linked to this zone they will also be disabled.

M-Valve – Use this mode to designate this zone as the master valve. It functions as a normally closed valve that turns

on when the flow zone is activated.

M-Val NO – Use this mode to designate this zone as a normally open master valve.

SprTime – Use this mode to set this zone for “sprinkle time,” which is a specialized, clock-based turn on/off mode. This

mode is not recommended for general use.

ET-Time – Use this mode to configure the zone to water based on Evapotranspiration settings. In order to use this device mode,

you must have a temperature sensor attached to the Remote Base Unit. Refer to Configuring an ET Primary Zone on page 55 for

more information.

Assign the zone to a program – Type a number in the

Prog#

(2)

field to associate this zone with a program.

Connect the zone to a flow zone – The fields under

FlowZone

(3)

are set to default values, but you can

change them. Refer to Setting Up Flow Monitoring for

Flow Zones on page 61.

Define the order for a “walk around” test – Type a

number in the Walk Around Order

(4)

field to define the

order the zone will run in during a “walk around” test.

Click the Check Walk Around

(5)

button to find zones

with the same walk around number.

Reorder the list of zones – Select the Advanced

(6)

option, and then type a new value in the Zone Reorder

(7)

field to change the order of the zones. If you add a

new zone that you want to use as a Linked or Mirrored

zone, you will need to place the new zone above the

others in the list. Use a decimal to move a zone between two others on the list. For example, type 3.5 in the Zone Reorder

field to insert a zone between the number 3 and 4 zones. To apply and save your changes, click the Reorder button at the

bottom of the column. To cancel any unapplied changes, click the Cancel button.