Transducer type – Baseline Systems BHM Series Hydrometer User Manual

Page 10

Advertising
background image

10

Hydrometers Operation and Maintenance Manual

Transducer Type

Transducer Type: Reed Switch and Photo Diode K Factors

Gallons per pulse

1

10

100

0.1

0.0053

Pulse per gallon

1

0.1

0.01

10

187.900

K factor 10.00

60.00

600.00

6000.00

6.00

0.319

Gallons per pulse

1

10

100

0.1

0.0085

Pulse per gallon

1

0.1

0.01

10

117.000

K factor 10.00

60.00

600.00

6000.00

6.00

0.5100

Gallons per pulse

1

10

100

0.1

0.0205

Pulse per gallon

1

0.1

0.01

10

48.710

K factor 10.00

60.00

600.00

6000.00

6.00

1.232

Gallons per pulse

1

10

100

1

0.0556

Pulse per gallon

1

0.1

0.01

10

17.993

K factor 10.00

60.00

600.00

6000.00

6.00

3.335

Gallons per pulse

10

100

1000

1

0.1741

Pulse per gallon

0.1

0.01

0.001

1

5.747

K factor 10.00

600.00

6000.00

60000.00

60.00

10.437

Gallons per pulse

10

100

1000

1

0.317

Pulse per gallon

0.1

0.01

0.001

1

3.152

K factor 10.00

600.00

6000.00

60000.00

60.00

19.036

Standard

Output

Optional Output

PD

PDH

Meter

Size

1½”

2”

3”

4”

6”

8”

Photo Diode (PD) and

Photo Diode High Frequency

Pulse (PDH)

Reed Switch (RS)

Note: Offset = 0 in all Netafim USA Water Meters

When entering K factors in controllers and/or data recorders please refer to the manufacturer’s

recommendations—some will require the number of gallons per pulse and others will require

the number of pulses per gallon. Some manufacturers will require a “K” and “offset” (for all

Netafim USA Water Meters the offset = 0) where the K and offset are calculated using he fol-

lowing equation:

Freq = (GPM/K) – offset

Where:

Freq = pulse/second

GPM = gallons per minute

K

= unit less constant specific to each hydrometer pulse output

Offset = correction factor (All Netafim USA water meters have an offset = 0)

or:

K

= 60/(pulse/gallon)