Hydrometers Operation and Maintenance Manual

Typical Applications

PRESSURE SUSTAINING

The pressure sustaining operation prevents the input pressure from falling below a predetermined

value. This application requires a Netafim Pressure Regulating Pilot Valve, or comparable valve.

Rotate the adjusting screw atop the pilot valve counterclockwise to increase the desired input

pressure and clockwise to reduce the desired input pressure.

Connection Information

The sensor connection runs from the input connector on the hydrometer to the controlled input

connector (1) on the pilot valve. The sensor connection also branches off to the “Close” connector

on the 3-Way Selector and to the vent connector (4) on the pilot valve.

The command connection runs from solenoid to the “Auto” connector on the 3-Way Selector

(via the shuttle valve) and continues on to the pressure controlled input connector (2) on the pilot

valve.

The supply connector (3) on the pilot valve serves as a vent. The output connector on the

hydrometer is not used.