Specifications, cont, Netafim usa hydrometers with electrical output – Baseline Systems BHM Series Hydrometer User Manual

Page 7

Advertising
background image

Hydrometers Operation and Maintenance Manual

7

Specifications, Cont.

NETAFIM USA HYDROMETERS WITH ELECTRICAL OUTPUT

Netafim USA Hydrometers are equipped with electrical output devices that combine the high reliability

of hermetically sealed, magnetically driven registers with a wide variety of electrical output options.

Hydrometers (measuring instruments) provide electrical output information about the flow of water.

When more than just the traditional register is needed, they also provide the solution for automation and

communication with controllers, electronic devices and other water delivery systems.

Netafim USA has three types of transducer outputs available which provide three levels of resolution:

• Reed Switch (RS) Register - low frequency pulse output for functions related

primarily to recording volume.

• Photo Diode (PD) Register - standard frequency pulse output (open collector) for

functions such as rate of flow and recording total volume.

• Photo Diode (PDH) Register - high frequency pulse (open collector) for functions

such as rate of flow and recording total volume.

ELECTRICAL OUTPUT SPECIFICATIONS
REED SWITCH (RS) REGISTER

The flow rate is transmitted as periodic electrical pulses are measured by the magnetic pointer in

the dial face. The hydrometer is configured to transmit a pulse according to a pre-defined volume

interval. The following summarizes the available volume intervals for various hydrometer sizes in

either gallons or cubic meters.
• A three pointer register, with a magnet installed on one of the pointers.

• Output definition: Volume Output

• Output type: RS – Reed Switch and PD – Photo Diode
The sensor is installed in a transparent plastic cover that can be mounted on the register in one of

three positions with the pointer facing the magnet. Three values of electrical output are available

in 1:10:100 ratios.

Manufacturer

Recommended

Register Type

Recommended Register

Transducer Outputs

Baseline

Basestation

PDH

Hunter

ACC 2-Wire

PDH

Rain Bird

MDC & Maxi

RS

Signature

All Models

RS

Toro

Sentinel

PDH

TDC 2-Wire

PDH

Rainmaster

All Models

RS (1” to 4”)

PD (6”, 8”)

Tucor

Flowmaster

PDH

& RK Series

Motorola

All Models

RS

Controller

Model

Advertising