Installation, cont, Control system – Baseline Systems BHM Series Hydrometer User Manual

Page 14

Advertising
background image

14

Hydrometers Operation and Maintenance Manual

Installation, Cont.

CONTROL SYSTEM

A. Solenoid Connection

The hydrometer receives commands from the controller or control center via an external solenoid

valve. The hydrometer may be ordered with a factory installed solenoid valve or connected to an

solenoid valve supplied by the user.

To connect to a factory installed solenoid:

1. Connect the electric cable from controller to the attached solenoid valve. Position

the three-way selector in the “Auto” position - in this position the hydrometer will be

controlled by the solenoid.

B. Electrical Output

The hydrometer supplies volume and flow rate data to a controller or to an external measuring

device via an electrical connection. A reed switch transducer is factory installed in the register

dial. The cable attached to the reed switch transducer attaches to the controller or measuring

device.

To connect the hydrometer to the controller or measuring device:

1. Install an appropriate connector onto the bare end of the cable exiting from the reed

switch. Refer to the user manual of the controller or measuring device for details

regarding the specific connector type.

2. Connect the cable to the input port of the controller or measuring device.

(See pages 7-10 for more details)