Hydrometers Operation and Maintenance Manual

31

Maintenance 3” and 4” Models, Cont.

INLET SPIDER AND STRAINER

Dis-assembly

• Loosen and remove the impeller bushing (36), the inlet

spider bearing nut (35) and the inlet spider bearing

washer (34).

• Remove the inlet spider tube (33).

• Inspect the inlet spider o-ring (32) and replace as

necessary.

Re-assembly

• Replace the inlet spider tube (33)

• Replace the inlet spider bearing washer (34) and nut

(35) onto the inlet spider shaft (31) and tighten.

• Replace the impeller bushing (36) into the inlet spider

nut (35).