Hydrometers Operation and Maintenance Manual

Maintenance 1½” and 2” Models, Cont.

INLET SPIDER AND STRAINER

Dis-assembly

• Loosen the impeller bushing (29) located atop the inlet

spider screw (24) and bushing (28). Pull the entire inlet

spider screw assembly up and out.

• Pull the inlet spider (27) upward and remove it from the

hydrometer body (21). Inspect for cracks or excessive

wear and replace as necessary.

• Remove and replace the body o-ring (26).

• Remove the strainer (25). Clean and inspect for damage or

excessive wear.

• Replace as necessary.

Re-assembly

• Place the body o-ring (26) in the small flange inside the

hydrometer base.

• Place the strainer (25) into the hydrometer base.

• Insert the inlet spider into the body so that the end rests on

the top of the strainer and the flange rests over the body

o-ring (26).

• Place the inlet spider screw assembly through the holes

in the input spider (27) and strainer (25). Use a socket

wrench to tighten the impeller bushing (29) atop the

assembly.