Dell POWEREDGE 2950 User Manual

Page 23

Advertising
background image

About Your System

23

E1711

PCI PERR B## D##

F##

PCI PERR Slot #

The system BIOS has reported a
PCI parity error on a component
that resides in PCI configuration
space at bus ##, device ##,
function ##.

The system BIOS has reported a
PCI parity error on a component
that resides in the specified PCI
slot.

Remove and reseat the PCI
expansion cards. If the problem
persists, see "Troubleshooting
Expansion Cards" on page 127.

Reinstall the expansion-card cage.
See "Expansion-Card Cage" on
page 78.

If the problem persists, the riser
card or system board is faulty. See
"Getting Help" on page 147.

E1712

PCI SERR B## D##

F##

PCI SERR Slot #

The system BIOS has reported a
PCI system error on a component
that resides in PCI configuration
space at bus ##, device ##,
function ##.

The system BIOS has reported a
PCI system error on a component
that resides in the specified slot.

Remove and reseat the PCI
expansion cards. If the problem
persists, see "Troubleshooting
Expansion Cards" on page 127.

Reinstall the expansion-card cage.
See "Expansion-Card Cage" on
page 78.

If the problem persists, the riser
card or system board is faulty. See
"Getting Help" on page 147.

E1714

Unknown Err

The system BIOS has determined
that there has been an error in the
system, but is unable to
determine its origin.

See "Getting Help" on page 147.

E171F

PCIE Fatal Err

B## D## F##

PCIE Fatal Err

Slot #

The system BIOS has reported a
PCIe fatal error on a component
that resides in PCI configuration
space at bus ##, device ##,
function ##.

The system BIOS has reported a
PCIe fatal error on a component
that resides in the specified slot.

Remove and reseat the PCI
expansion cards. If the problem
persists, see "Troubleshooting
Expansion Cards" on page 127.

Reinstall the expansion-card cage.
See "Expansion-Card Cage" on
page 78.

If the problem persists, the riser
card or system board is faulty. See
"Getting Help" on page 147.

E1810

HDD ## Fault

The SAS subsystem has
determined that hard drive ##
has experienced a fault.

See "Troubleshooting a Hard
Drive" on page 124.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

Book.book Page 23 Friday, February 3, 2006 11:09 AM

Advertising