About Your System

E2111

SBE Log Disable

Crd # DIMM ##

The system BIOS has disabled
memory single-bit error (SBE)
logging, and will not resume
logging further SBEs until the
system is rebooted. "##"
represents the DIMM implicated
by the BIOS. If no memory riser
card is present, the "Crd #" string
is left out of the message.

See "Troubleshooting System
Memory" on page 120.

E2112

Mem Spare Crd #

DIMM ##

The system BIOS has spared the
memory because it has
determined that the memory had
too many errors. "## & ##"
represents the DIMM pair
implicated by the BIOS. If no
memory card is present, the "Crd
#" string is left out of the
message.

See "Troubleshooting System
Memory" on page 120.

E2113

Mem Mirror Crd #

DIMM ## & ##

The system BIOS has disabled
memory mirroring because it has
determined that one half of the
mirror has had too many errors.
"## & ##" represents the
DIMM pair implicated by the
BIOS. If no memory card is
present, the "Crd #" string is left
out of the message.

See "Troubleshooting System
Memory" on page 120.

E2118

Fatal NB Mem CRC

One of the connections in the
Fully Buffered DIMM (FBD)
memory subsystem link on the
Northbound side has failed.

See "Troubleshooting System
Memory" on page 120.

E2119

Fatal SB Mem CRC

One of the connections in the
FBD memory subsystem link on
the Southbound side has failed.

See "Troubleshooting System
Memory" on page 120.

I1910

Intrusion

System cover has been removed.

Information only.

I1911

>3 ERRs Chk Log

LCD overflow message.

A maximum of three error
messages can display sequentially
on the LCD. The fourth message
displays as the standard overflow
message.

Check the SEL for details on the
events.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions