Dell POWEREDGE 2950 User Manual

Page 31

Advertising
background image

About Your System

31

Memory address line

failure at

address

, read

value

expecting

value

Faulty or improperly installed memory
modules.

See "Troubleshooting System Memory"
on page 120.

Memory double word logic

failure at

address

, read

value

expecting

value

Memory odd/even logic

failure at

address,

read

value

expecting

value

Memory write/read failure

at

address

, read

value

expecting

value

Memory tests terminated by

keystroke.

POST memory test terminated by
pressing the spacebar.

Information only.

No boot device available

Faulty or missing optical/diskette
drive subsystem, hard drive, or hard-
drive subsystem, or no boot disk in
drive A.

Use a bootable diskette, CD, or hard
drive. If the problem persists, see
"Troubleshooting a Diskette Drive" on
page 121, "T
roubleshooting an Optical
Drive" on page 123, and
"Troubleshooting a Hard Drive" on
page
124. See "Using the System Setup
Program" on page 37 for information on
setting the order of boot devices.

No boot sector on hard

drive

Incorrect configuration settings in
System Setup program, or no
operating system on hard drive.

Check the hard-drive configuration
settings in the System Setup program.
See "Using the System Setup Program"
on page 37. If necessary
, install the
operating system on your hard drive. See
your operating system documentation.

No timer tick interrupt

Faulty system board.

See “"Getting Help" on page 147."

Northbound merge error -

The following DIMM has

been disabled by BIOS:

DIMM x

The specified DIMM was unable to
establish a successful data link with
the memory controller.

See "Troubleshooting System Memory"
on page 120.

Not a boot diskette

No operating system on diskette.

Use a bootable diskette.

Table 1-7.

System Messages (continued)

Message

Causes

Corrective Actions

Book.book Page 31 Friday, February 3, 2006 11:09 AM