Dell POWEREDGE 2950 User Manual

Page 25

Advertising
background image

About Your System

25

E2016

Int Controller

Interrupt controller failure.

See "Getting Help" on page 147.

E2017

Timer Fail

Timer refresh failure.

See "Getting Help" on page 147.

E2018

Prog Timer

Programmable interval timer
error.

See "Getting Help" on page 147.

E2019

Parity Error

Parity error.

See "Getting Help" on page 147.

E201A

SIO Err

SIO failure.

See "Getting Help" on page 147.

E201B

Kybd Controller

Keyboard controller failure.

See "Getting Help" on page 147.

E201C

SMI Init

System management interrupt
(SMI) initialization failure.

See "Getting Help" on page 147.

E201D

Shutdown Test

BIOS shutdown test failure.

See "Getting Help" on page 147.

E201E

POST Mem Test

BIOS POST memory test failure. See "Troubleshooting System

Memory" on page 120. If problem
persists, see "Getting Help" on
page 147.

E201F

DRAC Config

Dell remote access controller
(DRAC) configuration failure.

Check screen for specific error
messages.

Ensure that DRAC cables and
connectors are properly seated. If
problem persists, see your DRAC
documentation.

E2020

CPU Config

CPU configuration failure.

Check screen for specific error
messages.

E2021

Memory

Population

Incorrect memory configuration.
Memory population order
incorrect.

Check screen for specific error
messages. See "Troubleshooting
System Memory" on page 120.

E2022

POST Fail

General failure after video.

Check screen for specific error
messages.

E2110

MBE Crd # DIMM ##

& ##

One of the DIMMs in the set
implicated by "## & ##" has
had a memory multi-bit error
(MBE). If no memory card is
present, the "Crd #" string is left
out of the message.

See "Troubleshooting System
Memory" on page 120.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

Book.book Page 25 Friday, February 3, 2006 11:09 AM