Five-wire heating/cooling system connections, Thermostats crestron chv-tstat and chv-thstat, Cg r w y – Crestron electronic CHV-TSTAT User Manual

Page 16: Backplate jumper from rh to rc

Advertising
background image

Thermostats Crestron

CHV-TSTAT and CHV-THSTAT

Five-Wire Heating/Cooling System Connections

CRESTRON ELECTRONICS

Jumper on P4

between pins 1

and 2

1
2

P4

Integrated

Control

Unit

C

G

R

W

Y

TOP

HU

M

RHU

RSR

RSR

RS

1

RS

2

24

(C

)

24

(R

)

24

V

Y

Z

G

NETWORK

RH

RC

G

Y/

Y1

Y2

O

B

W/

W1

W2

Backplate

Jumper

From RH

to RC

P1

P3

P6

P5

P4

1
2
3
4

Thermostat Circuit Board

C

G

R

W

Y


12

Thermostats: CHV-TSTAT and CHV-THSTAT

Operations and Installation Guide – DOC. 8163B