4. Device Options

Press the MODE button to access the DEVICE OPTIONS. Press VIEW to select
options. Press the Arrow keys (▲▼) to select the value of the parameter.

MODE

VIEW

T

T

CRESTRON

SETUP: DEVICE OPTS

Network ID:
LCD Contrast

Firmware
Version [1.1] Bld 133

2A
5

Select Network ID

Valid entries are 03 to FE in Hex
to match the network ID set for the
thermostat in SIMPL Windows

Select LCD Screen Contrast
(1 Lighter through 10 Darker)

5. Screen Options

Press the MODE button to access the SCREEN OPTIONS. Press VIEW to select
each option. Press the Arrow keys (▲▼) to select the value of the parameter.

NOTE: The pages in the following setup screen refer to the screens that are seen by
the user when the VIEW key is pressed in the normal operating mode.

Outdoor Page – Temperature/humidity of the outside sensor (if the optional sensor
is installed). May also be imported from Cresnet.

Global Page – Temperature/humidity selection for entire house. Allows setting of
temperature/humidity throughout a multi-thermostat system from a single location.
Must be wired and programmed as part of a Cresnet system.

Remote Function Page(s) – When part of a Cresnet system, remote function pages
allows control of other functions (for example: lights, alarms, etc.). Each of the two
pages has two definable buttons. The up ▲and down ▼ keys are set by indirect text
for each page, refer to “CHV-TSTAT and CHV-THSTAT Advanced Symbol” on
page 27.

MODE

VIEW

T

T

CRESTRON

SETUP: SCRN OPTIONS

Disp Global Page?
Disp Outdoor Page?
Disp Rem Func Pg1?
Disp Rem Func Pg2?

Y
Y
Y
Y

Display Global Page?
Yes or No

Display Outdoor Page?
Yes or No

Display Remote Function Pages?
Yes or No