Example programs, Viewport id string, Crestron chv-tstat and chv-thstat thermostats – Crestron electronic CHV-TSTAT User Manual

Page 41

Advertising
background image

Crestron CHV-TSTAT and CHV-THSTAT

Thermostats

Sensor Setup Related Digital Joins (continued)

Signal Name

Symbol

I/O

Definition

USE_R2_HUM_F

Advanced

Output

Asserted when using remote 2 humidity sensor

OMIT_LOC_HUM_F

Advanced

Output

Asserted when Omitting built in hum sensor (THSTAT)

OMIT_R1_HUM_F

Advanced

Output

Asserted when Omitting remote 1 humidity sensor

OMIT_R2_HUM_F

Advanced

Output

Asserted when Omitting remote 2 humidity sensor

R1_H_OUTDOOR_F

Advanced

Output

Asserted when remote 1 humidity sensor is outdoor

R2_H_OUTDOOR_F

Advanced

Output

Asserted when remote 2 humidity sensor is outdoor

Example Programs

Example programs for the thermostat are available from the Crestron FTP site
(

ftp://ftp.crestron.com

). Select the Examples Folder and search for: CHV-THSTAT

sample with scheduler.zip.

Viewport ID String

In Viewport, the thermostats output a string of characters that describe the setup and
configuration of the thermostat. Refer to the following table for an explanation of
this string. Each element of the setup string is separated by a period. The following
are two examples of ID strings:

2A: CHV-THSTAT [v1.0] (HP.H2.C2.HA3.CA3.ADB2.H,Abp0,90.AX.F.L5.OS0.DA.UUDDUU)

2B: CHV-THSTAT [v1.0] (H/C.H1.C1.HA3.CA3.ADB2.FA.F.L5.OS0.DA.UUOOOO)

ID Strings

Function Options

Description

System type

H/C, HP

Heat/cool or heat pump system

Heat stages

H1, H2

Number of heating stages, 1 or 2

Cool stages

C1, C2

Number of cooling stages, 1 or 2

Heat anticipator

HA1 - HA6

Heat anticipator setting, from 1-6

Cool anticipator

CA1 - CA6

Cooling anticipator setting, from 1 - 6

Auto-mode deadband

ADB2 - ADB6

Minimum separation between heat and cool setpoints in auto mode,
degrees, 2 - 6

Heat/cool system subtype

RAD, FA

Sub-type of heat/cool heating system RADiant or Forced Air

Heat pump system
subtype

AX, DF

Indicates heat pump system subtype as either AuXiliary heat or a Dual-
Fuel system

Heat pump/aux balance
points

0 - 90 for both

Indicates the heat pump and aux heat balance points in current
temperature unit

Temperature unit

F, C

Fahrenheit or Celsius

LCD contrast

L0-L10

LCD contrast setting

Temperature offset (null)

OS-6 - OS6

Indicates the display temperature offset, from -6 to 6 degrees

Auto mode operation

DA, SA

Indicates auto mode as dual setpoint (heat, cool setpoint) or single
setpoint mode

Sensor usage flags

U,D,O

Indicates the status of each sensor input: Use, outDoor, or Omit, sensor
series is as follows:
buit-in-temp; built-humidity; rem 1 temp; rem1 hum; rem 2 temp; rem 2
hum.

NOTE: Depending on system type, not all of the options above will be present.

Operations and Installation Guide – DOC. 8163B Thermostats:

CHV-TSTAT and CHV-THSTAT

37