Service/test, Crestron chv-tstat and chv-thstat thermostats – Crestron electronic CHV-TSTAT User Manual

Page 25

Advertising
background image

Crestron CHV-TSTAT and CHV-THSTAT

Thermostats

MODE

VIEW

T

T

CRESTRON

SETUP: SENSORS

Sensor

Internal:
Remote 1:
Remote 2:

TEMP HUM

USE OMIT
USE OMIT
USE OMIT

Internal Sensor
Temperature/Humidity in CHV-THSTAT
Temperature only in CHV-TSTAT
Remote Sensors
CHV-RTS temperature only sensor
CHV-RTHS temperature/humidity sensor
Sensors may be indoor or outdoor.
Choose USE, OMIT, or Outdoor (OD)

Select Sensor Type
Temperature and/or Humidity

NOTE: Remote 1 and Remote 2 Options do not appear on this screen if these
sensors are not connected.

NOTE: Declared outdoor temperature/humidity sensors should have both TEMP and
HUM declared as OD (Outdoor).

8. SERVICE/TEST

Press the MODE button to access the SERVICE/TEST setup screen. Press VIEW to
select each parameter. Press the Arrow keys (▲▼) to select the value of the
parameter.

• H1 – Single Stage Heating
• H2 – Two Stage Heating
• C1 – Single Stage Cooling
• C2 – Two Stage Cooling.

NOTE: This screen bypasses all system delays and is used by the installer to
manually operate the HVAC system. Only one system can be run at a time.

MODE

VIEW

T

T

CRESTRON

SETUP: SERVICE/TEST

Heat Call:
Cool Call:
Aux Heat Call:
Humidifier Call:
Fan Run Call:

OFF
OFF
OFF
OFF
OFF

Heat Call
Choose Off, H1, or H2

Cool Call
Choose Off, C1 or C2

Fan Run Call (ON or OFF)

Aux Heat (ON or Off)
Only appears on heat pump systems

Humidifier Call (On or Off) CHV-THSTAT only

Press MODE button to return to the first screen. Simultaneously press and hold the
MODE and VIEW buttons to return to normal operation mode.

Operations and Installation Guide – DOC. 8163B Thermostats:

CHV-TSTAT and CHV-THSTAT

21