4.2.8. Indicate optional column of figures in bottom line „u“ (75h)
The command is utilized to indicate a 5-digit column of figures in the bottom line of the display. The number is
indicated less dot respectively comma. Preceding zeroes as well as both arrows are suppressed. The upper line
still indicates the actual target or column of figures.
The column is indicated until any optional command except „t“, „u“ or „R“ is received by the interface. The
number will be retained after power failure.
Example: (column of figures = 012345)
SOH
Adr
Cmd
Column of figures = 012345
EOT
CRC
Transmission
01h
20h
75h
30h
31h
32h
33h
34h
35h
04h
B6h
SOH
Adr
Cmd
Column of figures = 012345
EOT
CRC
Response
01h
20h
75h
30h
31h
32h
33h
34h
35h
04h
B6h
Note:
Command “t” in conjunction with command “u” enables indication of a 10-digit number.
Both columns are not saved in EEPROM.