4.5. Specific commands

Command

code

Data amount

in bytes

read

write

Broad-

cast

Save in

EEPROM

Significance

K (4Bh)

-

-

X

X

X

Specific command: Profile reset (clear)

Q (51h)

1

-

X

X

X

Specific command: SPA reset

X (58h)

2 / 4 / 8

X

-

-

-

Specific command: Read device data


4.5.1. SPA profile reset „K“ (4Bh)

This command is clearing all previously programmed profiles.

Example 1: profile reset of a specific N SPA

SOH

Adr

Cmd

Data

EOT

CRC

Transmission

01h

20h

4Bh

7Fh

04h

C6h

SOH

Adr

Data

EOT

CRC

Response

01h

20h

6Fh

04h

52h N 150 replies by standard response ‚o’ (6Fh) = OK


Example 2: profile reset in all SPA by broadcast command (identifier=99)

SOH

Adr

Cmd

Data

EOT

CRC

Transmission

01h

83h

4Bh

7Fh

04h

DBh

Response

Not confirmed

Important: After profile reset all profile data are set to FFFFFFhex, the current profile number to FFhex.
The SPA display now is indicating 5 hyphens instead of target.

4.5.2. N 150 restore default „Q“ (51h)

This command restores default either of individual or collective parameters.

Data = q (71h) = Parameters restore default

Data = t (74h) = Device identifier = 98

Data = x (78h) = Multiturn counter reset to 0. No singleturn reset possible.

Data = ∆ (7Fh) = Enable all above functions.

Note: No profile reset. Profile reset by command „R“.

Example 1: Restore default in specific SPA

SOH

Adr

Cmd

Data

EOT

CRC

Transmission

01h

20h

51h

7Fh

04h

AEh

SOH

Adr

Data

EOT

CRC

Response

01h

20h

6Fh

04h

52h N 150 replies by standard response ‚o’ (6Fh) = OK


Example 2: Restore default in all SPA by broadcast command (identifier=99)

SOH

Adr

Cmd

Data

EOT

CRC

Transmission

01h

83h

51h

7Fh

04h

B3

Response

Not confirmed