Error warnings, Overview on commands, Crc error – Baumer N 150 User Manual

Page 19: Format error

Advertising
background image

N 150

www.baumer.com

19

5. Error warnings

5.1. CRC error

Upon recognizing a CRC error in a transmitted command the SPA will respond as follows:

SOH

Adr

Error EOT

CRC

Response

01h

20h

65h

04h

46h Error = „e“ (65h) = CRC error


5.2. Format error

Upon recognizing a format error (incorrect length of protocol or void command (Cmd) in a command transmitted
the SPA will respond as follows:

SOH

Adr

Error EOT

CRC

Response

01h

20h

66h

04h

40h Error = „f“ (66h) = Format error



6. Overview on commands

The following chart shows in alphabetical order all available commands (Cmd) as well as options regarding read
and write (parameterization).

Command

code

Data amount

in bytes

read

write

Broadcast

Save in

EEPROM

Significance

a (61h)

5

X

X

-

X

Read / write general parameter

b (62h)

8

X

X

-

X

Parameter: tolerance compensation, window

c (63h)

8

X

X

-

X

Parameter: scaling of spindle pitch

i (69h)

1

X

X

X

X

Parameter: mm / inch

t (74h)

6

-

X

-

-

Transmit tool number

u (75h)

6

-

X

-

-

Transmit optional column of figures

A (41h)

2

X

X

X

X

Assign or indicate device identifier

C (43h)

3

X

-

-

-

Check if actual value = target

K (4Bh)

-

-

X

X

X

Profile reset

Q (51h)

1

-

X

X

X

Specific command: N 150 reset

R (52h)

6

X

-

-

-

Read actual value

S (53h)

8

X

X

-

X

Read / write target

U (55h)

6

X

X

-

-

Offset

V (56h)

2

X

X

X

X

Read / write profile number

X (58h)

4

X

-

-

-

Specicfic command: read version number

Z (5Ah)

6

X

X

X

X

Set preset


Advertising