Read / write measuring unit „i“ (69h) – Baumer N 150 User Manual
Page 14
N 150
www.baumer.com
14
4.3.4. Read / write measuring unit „i“ (69h)
The command is utilized to read or write the measuring unit in mm or inches.
Data = 0 (30h) = mm
Data = 1 (31h) = inch
Example 1: Read parameter (setting = mm)
SOH
Adr
Cmd
EOT
CRC
Transmission
01h
20h
69h
04h
5E
SOH
Adr
Cmd
Data
EOT
CRC
Response
01h
20h
69h
30h
04h
D0h
Example 2: Change measuring unit to inch
SOH
Adr
Cmd
Data
EOT
CRC
Transmission
01h
20h
69h
31h
04h
D2
SOH
Adr
Cmd
Data
EOT
CRC
Response
01h
20h
69h
31h
04h
D2
Example 3: Write measuring unit mm into all N 150 by broadcast command (Identifier=99)
SOH
Adr
Cmd
Data
EOT
CRC
Transmission
01h
83h
69h
30h
04h
CDh
Response
Not confirmed
Important: Parameters are programmed in mm and auto-converted by N 150 into inches upon displaying the
position values.
.